SIN.EQRTUEVO1T

RTUEVO1T of the EQUOBOX system.

System for acquisition and storage of data from W.M-Bus 868 MHz / OMS EN13757 radio (through concentrators with Mesh Network technology) / cable.
Through a web interface, it allows the reading of the meters, the generation of reports, the setup, and the consultation of the historical readings.
Integrated graphic display for setup and data reading. Allows the storage of daily readings for 10 years.
Supports up to 2500 radio meters and 500 on two separate M-Bus lines (up to 20 meters via integrated M-Bus port).
Additional meters wired via SIN.EQLC1 and/or SIN.EQLC250.
Compatible with the highest IT security standards through encrypted protocols (https, SSL use for data transfer and sending).
SGH-compliant. Integrated SGHNET reachability service. 

 

GENERAL CHARACTERISTICS

  • M-Bus support wired on two separate communication lines

  • Supports 868 MHz M-Bus wireless multi-hop functionality via smart repeater sinapsitech℗

  • Up to 2500 wireless devices and 500 cable devices

  • Color graphic display

  • 3 digital inputs, 2 relay outputs

  • 24V AC/DC power supply

  • Meters/heat cost allocators/sensors query and data consultation via WEB interface

  • Ability to download reports on acquired data in CSV and Xls format

  • Email notification of events generated by the digital inputs and/or the status of the meters

  • Removable via LAN, ADSL, or UMTS/GPRS router

  • Compatibility with the highest IT security standards through encrypted protocols (https, SSL use for data transfer and sending)

  • A web interface reachability "0-configuration" via SGHNET

  • Sinapsi Global Hub (SGH) IoT Platform Compliant

ELECTRICAL CHARACTERISTICS

 

Power Supply

AC frequency

Maximum Power Consumption

AC/DC 24 V +/- 10% (SEV)

50/60 Hz

14.5 W, 15VA

Installation category

Class III

Ethernet N°1
RF

sinapsitechradio interface

M1, M2 Wired M-Bus interface max 20 dev.
A, B, C for further applications
B1, B2

for further applications

USB connection for further applications
Digital Inputs N°3 for dry contacts
Digital Outputs N°2 Relays


MECHANICAL CHARACTERISTICS
 

Temperature range

Operative: -10°C a +55°C / Storage: -25°C a +65°C

Dimensions

90x71x62 mm (HxLxP) – DIN

Mounting

35mm DIN Rail (EN60715)

Protection Grade

IP20 (EN60529)


WIRED M-BUS INTERFACE 

Reference standard

EN13757-2 (Physical Layer), EN13757-3 (Application Layer)

Baudrate

Min. 300bps – Max. 9600bps

Number of supported M-Bus meters

Without M-Bus repeaters: 20 (M1, M2); with repeaters:
max 500 by using at least one level converter for each Bus (A, B, C and M1, M2)

Reading frequency

15 min / 60 min / 6 hours / 12 hours / 1 day / 7 days/ 1 month

Recognition of collisions on M-Bus network

Yes

Devices search/acquisition

Via Primary and Secondary Address


WIRELESS INTERFACE

 

Radio communication protocol with
smart repeater sinapsitech
℗                                    

MESH / 868MHz

Number of supported Multi-hop repeaters

23

Number of supported W. M-Bus devices
[EN 13752-4] / OMS

2500 meters (through smart repeater sinapsitech/ each one supports 500 meters)


DATA LOGGING 

Data storage

1 year for intra-day data from wired meters,

2 months for intra-day data from radio meters

Reports

XLS, CSV, TXT format

Download report

Mail SMTP, FTP (S) (Client), Webserver (report generation and downloading)

Report scheduling

Daily / Weekly / Monthly / Two-monthly/ Three-monthly / Four-month/
Six-month/ Annually

USER INTERFACE 

Display

128x128px 262k colors graphic display

Keyboard

6 tactile membrane key

Led Power

Operating status

HTTPS (secure)

Multilanguage and secure (SSL) web server for data consulting/exporting and configuration


ALARMS

 

Alarm notification from M-Bus network

Anomalies /alarms meters, communication failure, thresholds violation

On board I/O

notification by e-mail of digital Inputs status
on-board output management

Check the Presetting List for pre-set objects with the Equobox system

 

CHANGE LOG

Find out about the latest firmware updates by downloading the RELEASE NOTES.
To download the file for the OFF-LINE update of the RTU firmware, you must first log-in and then download the appropriate file in the DOWNLOADS section above.

Click here to download the RELEASE NOTES

SIN.EQLC1
M-Bus LEVEL CONVERTER 60 Dev.
SIN.EQRPT868X
Wireless M-Bus EXTENDER
SIN.EQLC250
M-Bus LEVEL CONVERTER 250 Dev.
SIN.EQRPT868XT
Wireless M-Bus GATEWAY

WELCOME in SINAPSI's STORE !
We are SINAPSI, we are Italian and we have been passionately involved for almost 20 years in engineering, producing and distributing
devices and systems for monitoring consumption, energy and all sizes in the field.
Through our work we believe and want to generate savings, sustainability and give value to those who use our devices and contribute to a better world.